Pump Calibration ColumnsKoflo Pump Calibration Columns are an easy to use method for determining pump flowrate using industry standard graduations of milliliters/minute and gallons/hour. An equal starting point for both graduated scales gives the operator both ml/min. and GPH in one test. High contrast blue lettering enhances readability in all light conditions, and all scales have a protective Mylar lamination to protect against chemical attack. All sizes feature rugged construction using industrial grade PVC fittings.

Pump Calibration Columns Instructions

Operating Instructions
1. Install calibration column on the suction side of pump.
2. With valve A open and the pump operating, open valve B slowly until fluid level reaches the 0 mark.
3. Close valve A and begin timing with a stopwatch or wristwatch second hand.
4. At the one minute mark, observe fluid level. The observed level indicates the actual pump flowrate in mL/min and GPH.
5. When not in use, the calibration column should be drained, valve B closed and valve A opened.
CAPACITY MODEL NUMBER TUBE O.D. COLUMN HEIGHT FNPT END
CONNECTIONS
WEIGHT
FIXED CAPS TOP SLIP CAP

100 ML
0-1.5 GPH

100 ML

100 ML-SC

1.315”

12-1/2”

1/2”

7 oz.

250 ML
0-4 GPH

250 ML

250 ML-SC

1.650”

16-1/4”

1/2”

12 oz.

500 ML
0-8 GPH

500 ML

500 ML-SC

2.375”

16”

3/4”

22 oz.

1000 ML
0-16 GPH

1000 ML

1000 ML-SC

2.375”

25”

3/4”

30 oz.

2000 ML
0-32 GPH

2000 ML

2000 ML-SC

3.500”

24”

1”

4 lb.

4000 ML
0-64 GPH

4000 ML

4000 ML-SC

4.000”

34”

1”

6.5 lb.

10,000 ML
0-160 GPH

10,000 ML

10,000 ML-SC

6.625”

27”

2”

7.5 lb.

20,000 ML
0-320 GPH

20,000 ML

20,000 ML-SC

6.625”

46”

2”

10 lb.